Formula Scan™ - Basic Formulation

 

 

--------------------------------------------------------------------------------

 

 

 

 

Phosphate-free Liquid Autodish formulation

 

Item No.

Ingredients

Wt % AM

1

Water

41.32

2

4500MW PAA (45%)

14.00

3

KOH (45%)

22.20

4

Potassium silicate (20.9%)

5.88

5

Sodium hypochlorite (12%)

16.60

 

Total

100.00

 

Preparation:

At room temperature, in a suitable mixing vessel, under constant agitation add and mix items 1, 2, 3, 4, and 5 in and mix until a homogeneous mix is obtained.

 

 

 

 

Publish your formulation: Contact Formula Scan